@@ -6,33 +6,33 @@
|
||||
"contours": [
|
||||
{
|
||||
"sensor": "/devices/workroom_weather/controls/t",
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A6"
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A6/on"
|
||||
},
|
||||
{
|
||||
"sensor": "/devices/bathroom_weather/controls/t",
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A5"
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A5/on"
|
||||
},
|
||||
{
|
||||
"sensor": "/devices/entrance_weather/controls/t",
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A1"
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A1/on"
|
||||
},
|
||||
{
|
||||
"sensor": "/devices/corridor_weather/controls/t",
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A2"
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A2/on"
|
||||
},
|
||||
{
|
||||
"sensor": "/devices/techroom_weather/controls/t",
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A4"
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A4/on"
|
||||
},
|
||||
{
|
||||
"sensor": "/devices/kitchen_weather/controls/t",
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A3"
|
||||
"control": "/devices/wb-gpio/controls/EXT1_R3A3/on"
|
||||
}
|
||||
],
|
||||
"target_temperature": 21.0,
|
||||
"hysteresis": 0.5,
|
||||
"boiler_exhaust_t": "/devices/wb-w1/controls/28-000000860adf",
|
||||
"pump_control": "/devices/wb-gpio/controls/EXT1_R3A8",
|
||||
"boiler_control": "/devices/wb-gpio/controls/EXT1_R3A7"
|
||||
"pump_control": "/devices/wb-gpio/controls/EXT1_R3A8/on",
|
||||
"boiler_control": "/devices/wb-gpio/controls/EXT1_R3A7/on"
|
||||
}
|
||||
|
||||
+6
-3
@@ -25,12 +25,15 @@ class Contour:
|
||||
return self.current_value
|
||||
return None
|
||||
|
||||
def check_state(self, state_value):
|
||||
def check_state(self, state_value, force = False):
|
||||
if self.state == state_value:
|
||||
return
|
||||
if (self.state is None) or (time.time() - self.state_change_time > self.CHANGE_FREQ):
|
||||
return False
|
||||
if (self.state is None) or (time.time() - self.state_change_time > self.CHANGE_FREQ) or force:
|
||||
self.state = state_value
|
||||
self.state_change_time = time.time()
|
||||
self.logger.info("Contour " + self.sensor_topic + " changed state to " + str(self.state))
|
||||
return True
|
||||
return False
|
||||
|
||||
def update_target(self, target_value):
|
||||
self.target_value = target_value
|
||||
|
||||
+33
-17
@@ -105,10 +105,13 @@ def on_message(client, userdata, msg):
|
||||
|
||||
any_opened_start = 0
|
||||
any_opened = False
|
||||
boiler_out = 0
|
||||
pump_out = 0
|
||||
|
||||
|
||||
def check_temperatures():
|
||||
"""Check temperatures against target and control GPIO"""
|
||||
global any_opened_start, any_opened
|
||||
global any_opened_start, any_opened, boiler_out, pump_out
|
||||
# check boiler exhaust, turn off if too big
|
||||
if (boiler_exhaust_t > BOILER_EXHAUST_LIMIT):
|
||||
logger.error("Boiler exhaust overheat")
|
||||
@@ -116,9 +119,9 @@ def check_temperatures():
|
||||
# turn on the pump
|
||||
# and turn off the boiler of course
|
||||
for c in contours:
|
||||
mqtt_client.publish(c.out_topic, "1", retain=True)
|
||||
mqtt_client.publish(boiler_control, "0", retain=True)
|
||||
mqtt_client.publish(pump_control, "1", retain=True)
|
||||
c.check_state(True, True)
|
||||
boiler_out = 0
|
||||
pump_out = 1
|
||||
return
|
||||
#
|
||||
sum_t = 0
|
||||
@@ -132,9 +135,10 @@ def check_temperatures():
|
||||
if count_t == 0:
|
||||
logger.error("No temperatures available, switch to full-on mode")
|
||||
for c in contours:
|
||||
mqtt_client.publish(c.out_topic, "1", retain=True)
|
||||
c.check_state(True, True)
|
||||
# turn on boiler
|
||||
mqtt_client.publish(boiler_control, "1", retain=True)
|
||||
boiler_out = 1
|
||||
pump_out = 1
|
||||
return
|
||||
|
||||
for c in contours:
|
||||
@@ -143,20 +147,18 @@ def check_temperatures():
|
||||
# sensor is offline
|
||||
if contour_t is None:
|
||||
contour_t = sum_t / count_t
|
||||
logger.info("Contour " + c.sensor_topic + " has no data from sensor, using others' average")
|
||||
target_t = target_temp
|
||||
if not c.target_value is None:
|
||||
target_t = c.target_value
|
||||
if contour_t < target_t - hysteresis:
|
||||
# should turn on contour
|
||||
c.check_state(True)
|
||||
if c.check_state(True):
|
||||
logger.info("target: " + str(target_t) + " current: " + str(contour_t) + " hyst: " + str(hysteresis))
|
||||
if contour_t > target_t + hysteresis:
|
||||
# should turn off contour
|
||||
c.check_state(False)
|
||||
if c.state:
|
||||
# 0 means "closed"
|
||||
mqtt_client.publish(c.out_topic, "1", retain=True)
|
||||
else:
|
||||
mqtt_client.publish(c.out_topic, "0", retain=True)
|
||||
if c.check_state(False):
|
||||
logger.info("target: " + str(target_t) + " current: " + str(contour_t) + " hyst: " + str(hysteresis))
|
||||
|
||||
if any_opened:
|
||||
any_opened = False
|
||||
@@ -171,17 +173,31 @@ def check_temperatures():
|
||||
|
||||
logger.debug("Any opened: " + str(any_opened) + " aos " + str(any_opened_start) + " time " + str(time.time()))
|
||||
if any_opened and time.time() - any_opened_start > BOILER_TURN_ON_AFTER:
|
||||
mqtt_client.publish(boiler_control, "1", retain=True)
|
||||
mqtt_client.publish(pump_control, "1", retain=True)
|
||||
logger.info("Starting up pump and boiler, contours should be opened now")
|
||||
boiler_out = 1
|
||||
pump_out = 1
|
||||
else:
|
||||
mqtt_client.publish(boiler_control, "0", retain=True)
|
||||
mqtt_client.publish(pump_control, "0", retain=True)
|
||||
logger.info("All contours are considered closed, shutting down boiler and pump")
|
||||
boiler_out = 0
|
||||
pump_out = 0
|
||||
|
||||
def issue_commands():
|
||||
for c in contours:
|
||||
if c.state:
|
||||
# 0 means "opened"
|
||||
mqtt_client.publish(c.out_topic, 0, retain=True)
|
||||
else:
|
||||
mqtt_client.publish(c.out_topic, 1, retain=True)
|
||||
mqtt_client.publish(boiler_control, boiler_out, retain=True)
|
||||
mqtt_client.publish(pump_control, pump_out, retain=True)
|
||||
|
||||
|
||||
def main_cycle():
|
||||
"""Main 5-second cycle"""
|
||||
while True:
|
||||
try:
|
||||
check_temperatures()
|
||||
issue_commands()
|
||||
except Exception as e:
|
||||
logger.error(f"Error in main cycle: {e}")
|
||||
# Wait 5 seconds
|
||||
|
||||