Boiler and pump relays are inverted

This commit is contained in:
ftc
2025-12-15 22:29:22 +03:00
parent ca2cbc47f5
commit 875fad565e
+11 -7
View File
@@ -117,8 +117,9 @@ def check_temperatures():
# and turn off the boiler of course # and turn off the boiler of course
for c in contours: for c in contours:
mqtt_client.publish(c.out_topic, "1", retain=True) mqtt_client.publish(c.out_topic, "1", retain=True)
mqtt_client.publish(boiler_control, "0", retain=True) # boiler and pump relays are inverted in fact
mqtt_client.publish(pump_control, "1", retain=True) mqtt_client.publish(boiler_control, "1", retain=True)
mqtt_client.publish(pump_control, "0", retain=True)
return return
# #
sum_t = 0 sum_t = 0
@@ -133,8 +134,10 @@ def check_temperatures():
logger.error("No temperatures available, switch to full-on mode") logger.error("No temperatures available, switch to full-on mode")
for c in contours: for c in contours:
mqtt_client.publish(c.out_topic, "1", retain=True) mqtt_client.publish(c.out_topic, "1", retain=True)
# turn on boiler # boiler and pump relays are inverted in fact
mqtt_client.publish(boiler_control, "1", retain=True) # turn on boiler and pump
mqtt_client.publish(boiler_control, "0", retain=True)
mqtt_client.publish(pump_control, "0", retain=True)
return return
for c in contours: for c in contours:
@@ -170,12 +173,13 @@ def check_temperatures():
any_opened_start = time.time() any_opened_start = time.time()
logger.debug("Any opened: " + str(any_opened) + " aos " + str(any_opened_start) + " time " + str(time.time())) logger.debug("Any opened: " + str(any_opened) + " aos " + str(any_opened_start) + " time " + str(time.time()))
# boiler and pump relays are inverted in fact
if any_opened and time.time() - any_opened_start > BOILER_TURN_ON_AFTER: if any_opened and time.time() - any_opened_start > BOILER_TURN_ON_AFTER:
mqtt_client.publish(boiler_control, "1", retain=True)
mqtt_client.publish(pump_control, "1", retain=True)
else:
mqtt_client.publish(boiler_control, "0", retain=True) mqtt_client.publish(boiler_control, "0", retain=True)
mqtt_client.publish(pump_control, "0", retain=True) mqtt_client.publish(pump_control, "0", retain=True)
else:
mqtt_client.publish(boiler_control, "1", retain=True)
mqtt_client.publish(pump_control, "1", retain=True)
def main_cycle(): def main_cycle():